2022 Updated Verified Pass 5V0-21.21 Exam - Real Questions & Answers [Q26-Q43]

Share

2022 Updated Verified Pass 5V0-21.21 Exam - Real Questions and Answers

Dumps Moneyack Guarantee - 5V0-21.21 Dumps Approved Dumps


VMware 5V0-21.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Given a scenario, identify the use cases for an HCI Mesh infrastructure
Topic 2
  • identify the appropriate action to troubleshoot performance issues in a vSAN deployment
  • Identify vSAN data placement changes (stretches clusters, fault aomains)
Topic 3
  • Given a scenario, identify how to apply the appropriate maintenance mode option
  • Given a scenario, identify the apDropriate action to recover from a vSAN or infrastructure failure
Topic 4
  • identify the tasks to manape a stretches vSAN cluster
  • Identify the operational tasks required to manape an encrypted vSAN
Topic 5
  • VMware Products and Solutions
  • Given a scenario, identify the VMware products and solutions that will interact with a vSAN solution

 

NEW QUESTION 26
An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:
* Maximize the vSAN datastore usable capacity.
* Deduplication and compression are required to help utilize available capacity efficiency.
* Ensure the highest level of resiliency wherever possible.
Which disk group configuration should the architect include in the design?

  • A. Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.
  • B. Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.
  • C. Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.
  • D. One disk group per host, with one cache tier flash disk and four capacity tier flash disks.

Answer: B

 

NEW QUESTION 27
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1.
During the discovery phase, the consultant found the following information about the existing environment:
* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.
* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.
* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.
* The vSAN Cluster has the following configuration:
- vSAN version: 6.6.1
- Number of vSAN nodes: 10
- Encryption: enabled
- Deduplication and Compression: enabled
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- VMware vSphere ESXi version: 6.5 Update 3
- CPU: 2 processors, 20 cores
- RAM: 768GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)

  • A. The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.
  • B. The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.
  • C. The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).
  • D. The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).
  • E. The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.
  • F. The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.

Answer: A,C,E

Explanation:
https://blogs.vmware.com/virtualblocks/2018/10/29/a-closer-look-at-emm/

 

NEW QUESTION 28
In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

  • A. 50% of the reads comes from vSAN hosts on the local site
  • B. 50% of the reads comes from vSAN hosts on the remote site
  • C. 100% of the reads comes from vSAN hosts on the local site
  • D. 100% of the reads comes from vSAN hosts on the remote site

Answer: C

 

NEW QUESTION 29
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Create an HCI Mesh using the second cluster's datastore.
  • B. Obtain additional free capacity from the existing FC storage.
  • C. Create an HCI Mesh using the first cluster's datastore.
  • D. Obtain additional free capacity from the existing NAS storage.

Answer: A

Explanation:
https://blogs.vmware.com/virtualblocks/2020/09/16/introducing-vmware-vsan-hci-mesh/

 

NEW QUESTION 30
An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu.
Which solution mandates the use of VMware vSAN?

  • A. VMware Horizon
  • B. VMware Cloud Foundation
  • C. VMware Tanzu
  • D. VMware vRealize Automation

Answer: B

 

NEW QUESTION 31
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

  • A. Upgrade to VMware vCenter Server 7.0 U1.
  • B. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
  • C. Choose the Allow reduced redundancy option.
  • D. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
  • E. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
  • F. Disable vSAN Encryption before starting the upgrade process.

Answer: D

 

NEW QUESTION 32
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

  • A. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
  • B. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
  • C. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
  • D. Upgrade to VMware vCenter Server 7.0 U1.
  • E. Choose the Allow reduced redundancy option.
  • F. Disable vSAN Encryption before starting the upgrade process.

Answer: C,D,E

 

NEW QUESTION 33
In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

  • A. 100% of the reads comes from vSAN hosts on the local site
  • B. 100% of the reads comes from vSAN hosts on the remote site
  • C. 50% of the reads comes from vSAN hosts on the local site
  • D. 50% of the reads comes from vSAN hosts on the remote site

Answer: B

Explanation:
In the event of a failure or maintenance event, the virtual machine is restarted on the remote site. The 100% rule continues in the event of a failure. This means that the virtual machine will now read from the replica on the site to which it has failed over. One consideration is that there is no cached data on this site, so cache will need to warm for the virtual machine to achieve its previous levels of performance.

 

NEW QUESTION 34
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring
* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site - Preferred Site workloads should run on DC1 hosts.
* Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

  • A. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
  • B. Change the FTT setting in Policy 3 to be "Erasure Coding".
  • C. Change the Site Disaster Tolerance setting in Policy 4 to be "None - Keep Data on Preferred".
  • D. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
  • E. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".

Answer: C,D

 

NEW QUESTION 35
An administrator of "vsan-prod" cluster noticed the witness components of VMs are flagged as absent after a failed attempt to replace the vSAN Witness Host.
Which action should the administrator take to resolve this issue?

  • A. Using the RVC command: vsan.resync_dashboard ~/computers/vsan-prod
  • B. Placing the vSAN Witness Host in Maintenance Mode and adding to the vSAN cluster
  • C. Running the vSAN Skyline Health check to ensure there are vSAN Object Health errors and executing the Repair Object Immediately option
  • D. Upgrading the vSAN on-disk format

Answer: C

 

NEW QUESTION 36
An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:
* Maximize the vSAN datastore usable capacity.
* Deduplication and compression are required to help utilize available capacity efficiency.
* Ensure the highest level of resiliency wherever possible.
Which disk group configuration should the architect include in the design?

  • A. Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.
  • B. Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.
  • C. One disk group per host, with one cache tier flash disk and four capacity tier flash disks.
  • D. Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.

Answer: A

 

NEW QUESTION 37
An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.
Which three prerequisites must be satisfied before completing the task? (Choose three.)

  • A. Establish a trusted connection with the KMS
  • B. Enable Data-In-Transit encryption first
  • C. Create an encryption storage policy
  • D. Verify if a role with privilege "Cryptographic operations.Migrate" is assigned
  • E. Verify if a role with privilege "Cryptographic operations.Encrypt new" is assigned
  • F. Enable that the virtual machines are powered on

Answer: A,C,E

Explanation:
Because Before you can create encrypted virtual machines, you must create an encryption storage policy. You create the storage policy once, and assign it each time you encrypt a virtual machine or virtual disk. https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.security.doc/GUID-7DE1ED8F-880B-421E-B27B-5AAA58454AFA.html

 

NEW QUESTION 38
An administrator is planning to change a vSAN Storage Policy to apply a Failures To Tolerate (FTT) of 2, using RAID-6.
What is the minimum number of vSAN nodes required?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 39
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)

  • A. Put the affected vSAN host into maintenance mode to physically replace the storage device.
  • B. Replace the failed disk with a storage device that is identical in class and capacity.
  • C. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
  • D. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
  • E. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
  • F. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.

Answer: A,B,C

Explanation:
If you upgrade the capacity device, verify the following requirements:
- Verify that the cluster contains enough space to migrate the data from the capacity device.
- Place the host in maintenance mode. See Place a Member of Virtual SAN Cluster in Maintenance Mode.
"Select the flash capacity device or magnetic disk, and click Remove selected disk(s) from disk group."
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-4E3390C1-6C50-49E5-AEB6-C9BC037979A1.html

 

NEW QUESTION 40
A customer is planning to migrate their physical Microsoft SQL Server clustered workloads to vSAN enabled vSphere clusters.
The following requirements must be met:
* Each MSSQL cluster is made up of 3 nodes
* Highest possible availability against node failures
* Some of the vSAN clusters will only consume storage
What should the architect recommend?

  • A. vSAN Direct
  • B. vSAN iSCSI Target Service
  • C. Stretched vSAN Cluster
  • D. vSAN File Services

Answer: B

Explanation:
Reference:
vSAN 6.7 expands the functionality of the vSAN iSCSI Target service to provide the SCSI-3 persistent reservations support for shared disks for windows failover cluster if using the SQL Server FCI, high availability mode is a requirement. The vSAN iSCSI Target service at the vSAN cluster level should be enabled for this purpose. VSAN streched cluster may be used to increase the data availability across data centres. https://blogs.vmware.com/virtualblocks/2019/03/26/considerations-for-running-microsoft-sql-server-workloads-on-vmware-vsan/

 

NEW QUESTION 41
During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.
Which two commands must be run to extend the time? (Choose two.)

  • A. /etc/init.d/vsanobserver restart
  • B. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50
  • C. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80
  • D. /etc/init.d/vsanmgmtd restart
  • E. /etc/init.d/clomd restart

Answer: C,E

 

NEW QUESTION 42
data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?

  • A. Enable IOInsight Metrics.
    A minimum cluster of 2 vSAN ROBO nodes.
  • B. Enable performance services.
    A minimum cluster of 6 vSAN nodes.
  • C. Enable host build reserve.
    A minimum cluster of 4 vSAN nodes.
  • D. Enable operations reserve.
    A minimum cluster of 3 vSAN nodes.

Answer: C

 

NEW QUESTION 43
......

Updated PDF (New 2022) Actual VMware 5V0-21.21 Exam Questions: https://topexamcollection.pdfvce.com/VMware/5V0-21.21-exam-pdf-dumps.html