Updated PDF (New 2024) Actual EMC D-VXB-DY-A-24 Exam Questions [Q39-Q60]

Share

Updated PDF (New 2024) Actual EMC D-VXB-DY-A-24 Exam Questions

Verified D-VXB-DY-A-24 Exam Dumps PDF [2024] Access using PDFVCE


EMC D-VXB-DY-A-24 Exam Syllabus Topics:

TopicDetails
Topic 1
  • CPSD Technology Extension for Isilon: This domain covers the features and use of the CPSD (Cloud Platforms and Solutions Division) Technology Extension for Isilon, as well as its hardware components and advantages, for storage professionals and system integrators. Applicants must be knowledgeable about Isilon storage systems and how Dell EMC's converged infrastructure solutions work with them.
Topic 2
  • VxBlock Hardware Installation: For system administrators and data center technicians, this section of the exam covers the VxBlock System site installation process. It includes describing the installation steps, identifying key information in VxBlock System documentation, powering on and connecting the VxBlock System to the customer network, and troubleshooting the installation. Candidates should be prepared to demonstrate their knowledge of the entire installation lifecycle.
Topic 3
  • VxBlock Hardware Expansion Implementation: For data center architects and expansion project managers, this section examines the requirements and considerations for VxBlock hardware expansion. It includes locating required documentation and other resources supporting expansion. Candidates should be prepared to demonstrate their understanding of the expansion process and the ability to find and utilize relevant resources.
Topic 4
  • Cisco ACI Integration with DELL EMC CI Systems: This area focuses on Cisco ACI integration with Dell EMC CI solutions for network integration specialists. It includes defining the ACI Logical Model, outlining ACI interaction with Dell EMC VxBlock systems, and identifying ACI use cases, essential features, and relevant hardware. The use of Cisco ACI in Dell EMC setups and its implementation should be thoroughly understood by candidates.

 

NEW QUESTION # 39
What is the purpose of the Knowledge Transfer process with the customer?

  • A. Provide documents on critical items, such as naming conventions, IP address ranges, and component configurations
  • B. Introduce the customer team to their new converged or hyperconverged system
  • C. Provide generic information about VxBlock and its benefits
  • D. Provide in-depth training of the solution

Answer: B

Explanation:
* Introduction to the new system: The primary purpose of the Knowledge Transfer process is to introduce the customer team to their new converged or hyperconverged system1.
* Familiarization with the environment: This process involves familiarizing the customer's team with the environment and operational aspects of the VxBlock system1.
* Ensuring smooth transition: Knowledge Transfer is crucial for ensuring that the customer's team can effectively manage and maintain their new system1.
* Empowering the customer: By transferring knowledge, the customer's team is empowered to take full advantage of the system's capabilities and benefits1.


NEW QUESTION # 40
What type of topology does the ACI fabric use?

  • A. Flat
  • B. Tree
  • C. Hierarchical
  • D. Spine Leaf

Answer: D

Explanation:
* Review ACI Fabric Topology: The ACI fabric topology is based on a spine-leaf architecture, which is a scalable, two-layer network topology composed of spine switches and leaf switches1.
* Understand Spine-Leaf Benefits: This topology provides high-bandwidth connectivity between leaf switches and spine switches, allowing for efficient data flow across the network1.
* Recognize ACI Fabric Design: In an ACI fabric, each leaf switch connects to every spine switch, creating a non-blocking, high-throughput network that supports east-west traffic patterns typical in modern data centers1.
* Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would align with Cisco's guidelines on ACI fabric, which specify the spine-leaf topology as the standard for ACI deployments1.


NEW QUESTION # 41
A customer site has a VM in the VxBlock dedicated to a multicast application. The network monitoring team observes heavy network utilization each time the video streaming isrequested.
What should be enabled to address this issue?

  • A. VTP
  • B. LACP
  • C. IGMP
  • D. vPC

Answer: C

Explanation:
* Identify the Issue: Heavy network utilization during video streaming indicates that multicast traffic is not being efficiently managed1.
* Understand Multicast Traffic: Multicast applications use a single stream of data to deliver content to multiple recipients, which can cause network congestion if not handled properly1.
* Recognize IGMP's Role: Internet Group Management Protocol (IGMP) is used to manage multicast group memberships and is essential for optimizing multicast traffic on a network1.
* Implement IGMP: Enabling IGMP allows the network to efficiently distribute multicast traffic only to hosts that have explicitly requested it, reducing unnecessary network load1.


NEW QUESTION # 42
A System Engineer has completed a VxBlock 1000 system installation. What needs to be validated?

  • A. Storage processors are online and operational
  • B. Configuration of network, storage, compute, and virtualization
  • C. Network switches are installed as per the Build Guide
  • D. Management hosts are installed as per the Build guide

Answer: B

Explanation:
* Review VxBlock 1000 Installation: After completing the installation of a VxBlock 1000 system, it is crucial to validate the entire configuration to ensure all components are correctly set up and operational1.
* Validate Configuration: This includes checking the network setup, ensuring storage processors are online, verifying that management hosts are installed correctly, and confirming that the compute and virtualization layers are configured as per the design specifications1.
* Use Validation Tools: The Logical Configuration Survey (LCS) and Test Plan are typically used to validate a VxBlock 1000 installation, ensuring that all system elements are pre-integrated, pre-configured, and tested before being put into operation1.
* Ensure System Readiness: The validation process is essential to confirm that the system is ready for production use and that any potential issues are addressed before the system is handed over to the customer1.


NEW QUESTION # 43
What is the maximum number of X-Bricks that can be installed on a single XtremlO X2 array?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

Explanation:
* Review XtremIO X2 Specifications: The XtremIO X2 storage array is designed to support a scale-out architecture, allowing for the addition of multiple X-Bricks to increase capacity and performance1.
* Identify Maximum X-Bricks: According to the specifications, a single XtremIO X2 array can be scaled out to a maximum of 8 X-Bricks1.
* Understand Capacity Expansion: This scale-out capability enables the XtremIO X2 array to reach a large physical capacity, accommodating the storage needs of various applications and workloads1.
* Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would align with this information, providing details on the scalability options for the XtremIO X2 storage array1.


NEW QUESTION # 44
You are expanding a PowerMax 8000. What is the maximum allowed dispersion, in meters, between bricks?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
* Review PowerMax 8000 Specifications: The PowerMax 8000 is designed to support a dispersed configuration, allowing for flexibility in the physical placement of its components1.
* Identify Maximum Dispersion: The maximum allowed dispersion between bricks in a PowerMax 8000 system is up to 25 meters1.
* Understand Dispersion Considerations: This dispersion allows for the separation of individual or contiguous groups of system bays, providing options for physical layout within a data center1.
* Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would align with this specification, ensuring that the system meets both performance and physical space requirements1.


NEW QUESTION # 45
What is the responsibility of the Implementation Specialist during the deployment cycle?

  • A. Create the Site and Logical Configuration Surveys
  • B. Execute test plan and validation
  • C. Physically uncrate VxBlock racks and acclimatize
  • D. Perform inter-rack cabling

Answer: B

Explanation:
* Locate the validation procedures and support documentation: The Implementation Specialist must locate the necessary validation procedures and support documentation that are essential for the deployment of the VxBlock Systems1.
* Connect the VxBlock System to the customer network: After locating the documentation, the specialist is responsible for connecting the VxBlock System to the customer's network1.
* Validate a VxBlock 1000 installation using the LCS and Test Plan: The specialist must validate the VxBlock 1000 installation using the Lifecycle System (LCS) and the Test Plan to ensure that the system is correctly implemented and functioning as intended1.
* Describe how to perform knowledge transfers: Part of the specialist's role is to describe the process of knowledge transfer, ensuring that the customer's staff is adequately trained and informed about the system1.


NEW QUESTION # 46
What is a key benefit VxLAN?

  • A. It enables inter-VM communications among data center servers in different Layer 2 subnets.
  • B. It can be configured in the hypervisor to support an NSX implementation.
  • C. It reduces implementation cost of multiple VxBlock systems sharing data centers.
  • D. It enables vMotion over Layer 3 subnets across geographic locations.

Answer: D

Explanation:
* Understand VxLAN: VxLAN, or Virtual Extensible LAN, is a network virtualization technology that allows for the creation of a Layer 2 network on top of a Layer 3 network1.
* Identify Key Benefit: One of the key benefits of VxLAN is that it enables vMotion to occur over Layer
3 subnets, which can span across different geographic locations1.
* Recognize VxLAN Capabilities: By encapsulating Layer 2 Ethernet frames into Layer 4 UDP packets, VxLAN allows for the extension of networks over long distances, facilitating vMotion in environments where the physical network infrastructure is spread out1.
* Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would align with this understanding of VxLAN, highlighting its ability to support vMotion across Layer 3 subnets as a significant advantage1.


NEW QUESTION # 47
Which logical entity in ACI allows for logical separation and reuse of IP address space within an ACI fabric?

  • A. Tenant
  • B. VLAN
  • C. Context
  • D. EPG

Answer: A

Explanation:
In ACI (Application Centric Infrastructure), the logical entity that allows for logical separation and reuse of IP address space within an ACI fabric is the Tenant. A Tenant represents a unit of isolation from a policy perspective and allows for the segmentation of the network into multiple virtual environments, each with its own policies and IP address spaces.
References:
* Cisco ACI documentation.
* Technical resources on ACI architecture and logical entities.


NEW QUESTION # 48
In which cluster does the NSX Controller reside on a VxBlock system?

  • A. Production
  • B. Edge
  • C. Management
  • D. Control

Answer: C

Explanation:
In a VxBlock system, the NSX Controller resides in the Management cluster. The Management cluster is responsible for housing management components and services, ensuring centralized control and management of the NSX environment.
References:
* Dell EMC VxBlock system documentation.
* VMware NSX deployment and architecture guides.


NEW QUESTION # 49

Refer to the exhibit.
A cable with the following label was connected to the wrong equipment type:
* M91A-01:01 U61A-01:09
Based on the exhibit, what is the target equipment type?

  • A. Nexus 9xxx, Slot A, Port1
  • B. MDS 9xxx, Slot 1, Port 1
  • C. UCS 6xxx FI, Uplink A, Slot 1, port 9
  • D. UCS 5108 Chasses A, Slot 1, Port 9

Answer: B

Explanation:
The label on the cable indicates two parts: "M91A-01:01" and "U61A-01:09". The first part of the label
"M91A" refers to a specific type of equipment as per the exhibit. According to the exhibit, "M9" corresponds to "MDS 9xxx", which is a Cisco Multilayer Director Switch. The second part of the label, "U61A", does not directly match any category in the provided list; however, it seems to be an internal reference that could be related to user-specific configurations or locations.
Since we are looking for the target equipment type and not where it was mistakenly connected, we focus on the first part of the cable label. The numbers following "M91A" indicate slot and port information. Therefore, based on this labeling system and referring to the exhibit provided, which lists various EMC and Cisco equipment types along with their corresponding codes (like AP for APIC Appliance or CN for Cust. Network), we can deduce that "M91A" stands for "MDS 9xxx". The subsequent numbers "-01:01" suggest Slot 1, Port 1.


NEW QUESTION # 50
A System Engineer is validating system cabling for a VxBlock 1000. They find that some ports on Fabric Interconnects 1A are not connected.
Which connections are missing?

  • A. Network uplinks to the customer network
  • B. SAN uplinks to MDS switches
  • C. Server uplinks to C-Series servers
  • D. Network uplinks to Nexus switches

Answer: C

Explanation:
* Review the VxBlock 1000 documentation: The System Engineer should review the VxBlock 1000 documentation to understand the standard cabling configuration for Fabric Interconnects1.
* Identify the role of Fabric Interconnects 1A: Fabric Interconnects serve as the nerve center for data and storage networking in the VxBlock 1000.They manage the connectivity between the compute, storage, and networks1.
* Determine the standard connection setup: Typically, Fabric Interconnects 1A would have server uplinks connected to the C-Series servers to manage data traffic between servers and the rest of the network2.
* Validate against the deployment checklist: The System Engineer should validate the cabling against the deployment checklist provided in the VxBlock Deploy Achievement document to ensure all connections are correctly made1.


NEW QUESTION # 51
Which statement about the differences between Cisco ACI and VMware NSX is NOT correct?

  • A. NSX supports both x86 and non-x86 servers; ACI does not
  • B. NSX is network topology independent; ACI supports only spine-leaf architecture
  • C. NSX requires a gateway for the physical environment; ACI works the same for physical and virtual environments
  • D. NSX is hardware independent; ACI is hardware dependent

Answer: A

Explanation:
* Review the Core Differences: Both Cisco ACI and VMware NSX have similar qualities and features.The main difference is that VMware NSX focuses on virtualized networks, while Cisco ACI can connect to both physical and virtual networks1.
* Identify Incorrect Statement: The statement that NSX supports both x86 and non-x86 servers; ACI does not is not correct.Cisco ACI is not limited to x86 servers and can work with a variety of hardware platforms1.
* Understand ACI's Capabilities: Cisco ACI is an integrated solution that addresses both the physical and virtual networks, providing a policy-driven framework that is not limited by server architecture1.
* Validate with Documentation: The Official Dell VxBlock Deploy Achievement document would align with this understanding, as it would detail the capabilities of Cisco ACI in working with different network and server environments1.


NEW QUESTION # 52
Match each team member with their RACI role.

Answer:

Explanation:

Explanation:
Match each team member with their RACI role as follows:
* Project Manager: Primary point of contact; manages overall project and communications
* Assessment Team Lead: Ensures proper assessment execution and validates upgrade sequence plan
* Assessment Team: Communicates upgrade progress and issues to the PM
* Delivery Manager: Transitions requirements and upgrade plan to the upgrade team
* Upgrade Team: Point of contact for internal escalations
* Project Manager: Primary point of contact; manages overall project and communications
* The Project Manager is responsible for overseeing the entire project, coordinating all activities, and serving as the main point of contact for stakeholders.
* Assessment Team Lead: Ensures proper assessment execution and validates upgrade sequence plan
* The Assessment Team Lead oversees the assessment phase, ensuring that the evaluation is thorough and that the upgrade sequence is properly planned and validated.
* Assessment Team: Communicates upgrade progress and issues to the PM
* The Assessment Team members are responsible for executing the assessment tasks and reporting progress and any issues encountered to the Project Manager.
* Delivery Manager: Transitions requirements and upgrade plan to the upgrade team
* The Delivery Manager is responsible for ensuring that all requirements and the upgrade plan are effectively communicated and handed over to the upgrade team for execution.
* Upgrade Team: Point of contact for internal escalations
* The Upgrade Team handles the actual upgrade process and serves as the primary point of contact for any internal escalations that may arise during the upgrade.
References:
* Dell EMC project management and RACI documentation.
* Industry best practices for defining roles and responsibilities in a RACI matrix.


NEW QUESTION # 53
What type of topology does the ACI fabric use?

  • A. Flat
  • B. Tree
  • C. Hierarchical
  • D. Spine Leaf

Answer: D

Explanation:
* Review ACI Fabric Topology: The ACI fabric topology is based on a spine-leaf architecture, which is a scalable, two-layer network topology composed of spine switches and leaf switches1.
* Understand Spine-Leaf Benefits: This topology provides high-bandwidth connectivity between leaf switches and spine switches, allowing for efficient data flow across the network1.
* Recognize ACI Fabric Design: In an ACI fabric, each leaf switch connects to every spine switch, creating a non-blocking, high-throughput network that supports east-west traffic patterns typical in modern data centers1.
* Reference Official Documentation: The Official Dell VxBlock Deploy Achievement document would align with Cisco's guidelines on ACI fabric, which specify the spine-leaf topology as the standard for ACI deployments1.


NEW QUESTION # 54
A customer engineer is unable to securely connect to vCenter using their laptop. Both the vCenter and the customer laptop are behind a firewall. The network security teamrequests that the customer engineer provide source and destination port numbers to establish the needed connection.
What ranges of source and destination port numbers are valid?

  • A. Source port: 49152 - 65535
    Destination port: 442
  • B. Source port: 49152 - 65535
    Destination port: 443
  • C. Source port: 1 - 65535
    Destination port: 443
  • D. Source port: 1024 - 49151
    Destination port: 442

Answer: B

Explanation:
When securely connecting to vCenter, the customer engineer needs to provide the correct source and destination port numbers. The valid source port range for secure connections is typically from 49152 to 65535, which are ephemeral ports assigned by the operating system for outbound connections. The destination port for secure connections to vCenter is 443, which is the standard port for HTTPS.
References:
* VMware vCenter documentation.
* Networking standards for secure HTTPS connections.


NEW QUESTION # 55
Which data layout technique is used on an Isilon cluster?

  • A. Error Correction Code (ECC)
  • B. Backward Correction Error (BCR)
  • C. Parity Correction Error (PCR)
  • D. Forward Correction Error (FEC)

Answer: D

Explanation:
The data layout technique used on an Isilon cluster is Forward Correction Error (FEC). This method ensures data integrity and availability by distributing error correction information across the nodes in the cluster, allowing for data recovery in the event of hardware failures.
References:
* Dell EMC Isilon OneFS technical documentation.
* Information on data protection techniques in distributed storage systems.


NEW QUESTION # 56
What is the recommended source to download a Test Plan for a specific VxBlock model?

  • A. https://vce.flexnetoperations.com
  • B. DellEMC Support
  • C. SolVe Online
  • D. https://cpsdocs.dellemc.com/

Answer: C

Explanation:
* Access SolVe Online: SolVe Online is Dell EMC's online tool that provides step-by-step procedures and support for various products, including VxBlock Systems1.
* Navigate to VxBlock Section: Within SolVe Online, navigate to the section dedicated to VxBlock Systems to find resources specific to these models1.
* Locate Test Plan: Look for the Test Plan associated with the specific VxBlock model you are working with.The Test Plan is typically available in the form of downloadable documents or guides1.
* Download Test Plan: Once located, download the Test Plan for the specific VxBlock model to use as a reference for deployment or troubleshooting1.
* Verify with Documentation: Ensure that the downloaded Test Plan matches the model and version of the VxBlock System you are using by cross-referencing with the official documentation1.


NEW QUESTION # 57
Which document provides a representation of all the connections on the recently upgraded switch?

  • A. Switch Release Notes
  • B. Solutions Abstract
  • C. Switch Administration Guide
  • D. Port Map

Answer: D

Explanation:
* Identify the Correct Document: The Port Map is typically used to provide a visual representation of all the connections on a network switch, including those that have been recently upgraded1.
* Understand the Purpose of a Port Map: A Port Map is a detailed diagram that shows the physical and logical connections to and from a network switch.It is an essential tool for network administrators to visualize the network topology and troubleshoot connectivity issues1.
* Utilize the Port Map: After an upgrade, the Port Map can be referenced to verify that all connections have been correctly re-established and that the switch is functioning as expected within the network infrastructure1.


NEW QUESTION # 58
Which component is NOT part of the Cisco ACI solution?

  • A. Cisco ACI End Point Group
  • B. Cisco Nexus 7000 series switches
  • C. Cisco Application Policy Infrastructure Controller
  • D. Cisco Nexus 9000 series switches

Answer: B

Explanation:
* Review Cisco ACI Components: Cisco ACI is a comprehensive networking solution for data centers
* that includes specific components designed to work within its architecture1.
* Identify Non-ACI Component: The Cisco Nexus 7000 series switches are not part of the Cisco ACI solution.Cisco ACI is built on Cisco Nexus 9000 series spine and leaf switches1.
* Understand ACI Architecture: The Cisco ACI architecture is designed around the Cisco Application Policy Infrastructure Controller (APIC) and the Nexus 9000 series switches, which work together to provide a policy-driven solution that automates network provisioning and control1.
* Recognize ACI Specific Entities: The Cisco ACI End Point Group (EPG) is a fundamental entity within the ACI architecture that groups together similar endpoints with common policy requirements1.


NEW QUESTION # 59
A customer is planning to integrate a VxBlock to a new Cisco ACI fabric. What major physical connectivity change is needed if the customer intends to convert their existing VxBlock Nexus 9396PX switches to ACI mode?

  • A. Connect the switch directly to the APIC to download the ACI software. Then connect the existing Nexus
    9396PX switches to a spine Nexus 93180YC switch.
  • B. Nexus 9396PX switch cannot be integrated directly to ACI fabric.
  • C. Connect the Nexus 9396PX switch to spine Nexus 9500 switches. Remove other connections between the Nexus 9396PX switches.
  • D. Remove the dual peer link connection but keep the peer link connection for ACI fabric heartbeat traffic exchange.

Answer: A

Explanation:
To convert existing VxBlock Nexus 9396PX switches to ACI mode, a major physical connectivity change involves connecting the switch directly to the APIC (Application Policy Infrastructure Controller) to download the ACI software. Afterward, the existing Nexus 9396PX switches should be connected to a spine Nexus 93180YC switch as part of the ACI fabric setup.
References:
* Cisco ACI deployment guides.
* Dell EMC VxBlock system integration documentation.